Water Analysis System |
|
CL-200 |
|
Mode |
Range |
Accuracy |
Ph |
0.00 - 14.00 |
+ / - 0.01 |
TDS |
00 to 1999 PPM |
2% F.S. |
|
00 to 19.99 PPT |
|
Conductivity |
00 to 1999 MICRO S |
2% F.S. |
|
00 to 19.99 MILLI S |
|
Temperature |
0 to 100 Deg C |
2 Deg C |
DO |
0 to 20.0 PPM |
|
Read out |
LCD |
|
Accessories |
- PH Electrodes |
|
- TDS Probe |
|
- D.O. Probe |
|
- Temp Probe |
|
- Conductivity cell |
|
- Electrode stand, holding clamp buffers |
|
|
|
|
|
CL-201 |
|
CL -201 IS BATTERY/MAINS OPERATED MICRO CONTROLLER
BASED INSTRUMENT IN BRIFE CASE FOR ESTIMATION FOR PH, CONDUCTIIVITY,TDS,MV,DISSOLVED OXYGEN (D.O.) AND TEMPERATURE MEASUREMENT IN WATER, WASTE WATER AND
BIOLOGICAL APPLICATIONS PH METER IS USED FOR MESUREMENT. MEASUREMENTS ARE
DISPLAYED BY A 20 * 4 DIGIT ALPHA NUMERIC LCD. |
|
Mode |
Range |
Accuracy |
Resolution |
Ph |
0.00 - 14.00 |
0.01 +/- 1 Digit |
0.01 PH |
|
Calibration: 2-3 Point |
|
|
MV |
+/- 1999 MV |
1.0 mV +/- 1 Digit |
0.1 mV |
CONDUCTIVITY |
0.1 μS - 100 mS |
1% OF F.S +/- 1 Digit |
0.1 μS |
TDS |
0.1 PPM - 100 PPT |
1% OF F.S +/- 1 Digit |
0.1 PPM |
Temperature |
0 to 100 Deg C |
1 Deg C |
0.1 Deg C |
DO |
0 to 20.0 PPM |
1% OF F.S +/- 1 Digit |
0.1 PPM |
|
SALINITY : 0 40 PPM |
|
|
Display |
- 20 * 4 LCD |
PRINTER PORT |
- 80 COLUMN DOT MATRIX |
POWER |
- 230 V 50 HZ WITH INTERNAL BATTERY CHARGER |
|
|
Accessories |
- Combined Electrode |
|
- Conductivity Cell 1.0 CC |
|
- D.O. Probe Au/Ag |
|
- Temp Probe PT 100 |
|
- Cond. cell |
Temp. Compensation |
- Auto and Manual |
|
|
|
|
|
CL-202 |
|
Mode |
Range |
Accuracy |
Resolution |
Ph |
0.00 - 14.00 |
0.01 +/- 1 Digit |
0.01 PH |
|
Sensor : Combined Electrode |
MV |
+/- 1999 MV |
1.0 mV +/- 1 Digit |
0.1 mV |
|
Sensor : Combined Electrode |
CONDUCTIVITY |
0.1 μS - 100 mS |
1% OF F.S 1 Digit |
|
TDS |
0.1 PPM - 100 PPT |
1% OF F.S 1 Digit |
|
|
Sensor : Conductivity Cell 1.0 CC, Acceptable (0.1 to 5.0) |
Temperature Comp. |
- Auto and Manual |
Temperature |
0 to 100 Deg C |
|
|
DO |
0 to 20.0 PPM |
1% OF F.S 1 Digit |
0.1 PPM |
|
Salinity : 0 40 PPM |
|
Sensor : Au / Ag Probe |
COLORIMETER |
0 TO 2.00 ABS |
0.05 ABS |
0.01 ABS/ 1% T |
|
Sensor : Photo diode |
|
Source : Tungsten Lamp |
|
Filters : Blue 440, Green 540, Red 660 |
TURBIDITY |
0 - 10 NTU TO 100NTU |
2% OF F.S +/- 1 Digit |
|
|
Sensor : Photo Diode |
|
Source : Tungsten Lamp |
Display |
- 3 1/2 DIGIT LCD |
POWER |
- 230 V 50 HZ WITH INTERNAL BATTERY CHARGER |
|
|
Accessories |
- Combined Electrode |
|
- Conductivity Cell 1.0 CC |
|
- D.O. Probe |
|
- Temp Probe |
|
- 4 No. Test Tube for Colori & Turbidity Meter |
|
- 3 Filters |
|
|
|
|
|
CL-203 |
|
CL -203 IS BATTERY/MAINS
OPERATED MICRO CONTROLLER BASED INSTRUMENT IN BRIFE CASE
FOR ESTIMATION FOR PH, CONDUCTIIVITY, TDS,MV,DISSOLVED OXYGEN
(D.O.),TURBIDITY ,COLORI AND TEMPERATURE MEASUREMENT IN WATER,
WASTE WATER AND BIOLOGICAL APPLICATIONS PH METER IS USED FOR
MESUREMENT. MEASUREMENTS ARE DISPLAYED BY A 20 * 4 DIGIT
ALPHA NUMERIC LCD. |
|
Mode |
Range |
Accuracy |
Resolution |
Ph |
0.00 - 14.00 |
0.01 +/- 1 Digit |
0.01 PH |
|
Calibration: 2-3 point |
DO |
0 to 20.0 PPM |
1% OF F.S +/- 1 Digit |
0.1 PPM |
|
Salinity : 0 40 PPM |
COLORIMETER |
0 TO 2.00 ABS |
0.05 ABS |
0.01 ABS/ 1% T |
|
0 TO 100% T |
0.5% T |
0.1% T |
|
0 TO 9999C |
|
BY FACTOR |
|
Sensor : Photo Diode |
|
Source : Tungsten Lamp |
|
Filters : Blue 440, Green 540, Red 660 |
TURBIDITY |
0 TO 10 NTU |
2% OF F.S +/- 1 Digit |
0.1 NTU |
|
0 TO 100 NTU |
|
0 TO 500 NTU |
|
Sensor : Photo Diode |
|
Source : Tungsten Lamp |
Display |
- 20 * 4 DIGIT LCD |
PRINTER PORT |
- 80 COLUMN DOT MATRIX |
POWER |
- 230 V 50 HZ WITH INTERNAL BATTERY CHARGER |
|
|
Accessories |
- Combined Electrode |
|
- Conductivity Cell 1.0 CC |
|
- D.O. Probe Au/Ag Probe |
|
- Temp Probe PT100 |
|
- 4 No. Test Tube for Colori |
|
- 3 Filters Blue 440, Green 540, Red 660 |
|
- Test Tube (25 * 4)MM 4 Nos. for Turbidity |
|
- Light Shield |
Temp Comp. |
- Auto and Manual |
|
|
|
|
|